DPL monoblock progressive dividers ILC interchangeable with SSV progressive metering devices Lincoln


TECHNICAL FEATURES


Operating pressure

·

From 15 to 300 Bar

Lubricants (at minimum operating temperature)

·

Mineral oil minimum 46 cSt or Grease maximum NLGI-2

Operating temperature

·

From -40 °C to 110 °C

Discharge (for outlet)

·

200 mm³/cycle

Inlet port

·

1/8 BSP

Check valve

·

Standard in the inlet

Outlet port

·

M10x1

Outlets

·

from 6 to 20

Piston cycles

·

Max 350/min

Coating

·

Zinc-Nickel plated

Marking

·

ATEX II GD - CE

Metering devices

·

Steel, Zn-Ni plated (free of Cr-VI)


ADVANTAGES


- Standard inlet check valve

- Easier configuration with less pistons

- Even possible to close one of the last two outputs

- Two different ways to join outlets

- Plug for conveying in the next output

- Separation screw for one single outlet